Product Show

Photoelectric switch

FFD-GD03A


. Summary

     Photoelectric switch is a photoelectric switch developed according to the specific needs of elevator industry. It is mainly used to obtain elevator well signal, such as gate signal, flat layer signal, speed change signal and end station signal. Widely used in elevator control and elevator monitoring. The photoelectric switch can also be used in other industrial fields.

. Use of work instructions

 

  1According to the corresponding wiring: red / brown-power positive or negative; yellow / blue-power positive or negative; green / black-output.

  2Check that the action of the indicator lamp is normal.

3During the work of this product, the green indicator light is on and the output level is high (24 V). When blocking the light path with a non-transparent object, the red indicator light is converted to output low level (0 V). A normally closed photoelectric switch lights a red indicator when there is no object blocking the light path and outputs a low level (0 V). When blocking the light path with a non-transparent object, it is converted into a green indicator light and outputs a high level (24 V). (often on or off can be replaced by changing the polarity of the positive and negative poles of the power supply, the upgraded version is no blocking red light, blocking red light out).

 . Technical parameters

 Detection distance

30 mm slot width

 30 mm slot width

Φ4mm Above non-transparent

 Minimum detection object

φ2mm Above non-transparent

 Power supply voltageVS

DC12-30V

 Protection circuit

Output short circuit protection, overcurrent protection, overheating protection

 Control output

Output voltage VS-1, output current ≤200 mA, power supply polarity can be changed

Response time

Action, reset: below 1 ms each

 ambient temperature

At work, save :-20-70

 At work, save :-20-70

Work time :35-85%; save time :35-95%(no condensation)

 Protection level

IP-64`

 Connection mode

Conductor lead type, conductor length 120 CM

. Output loop

 

Note: the output polarity can be changed by changing the positive and negative polarity of the access power supply!

五. Working principle

The photoelectric switch adopts high quality infrared transmitter and infrared receiver, as well as corresponding oscillation circuit and receiving drive circuit. The oscillating circuit produces high frequency oscillation wave with fixed frequency and drives the infrared transmitting circuit to send out high frequency infrared pulse. This process is called transmitting wave modulation. The receiving circuit receives infrared pulse wave and drives the corresponding driving circuit to drive the external load. This process is called infrared demodulation. When the transmitting circuit and the receiving circuit are blocked, the receiving circuit can not receive the infrared high frequency pulse wave, resulting in the level flip, so that the level of the driving external circuit changes, thus detecting that the optical circuit is blocked!

. Logical Relation and Connection Comparison Table

 Logical relations

Wiring

 Often on (shading output high level)

 Red/brown/negative (-)

 Red/brown - positive ()OUT

 Yellow/blue - positive+

 normally closed (shading output low level)

 Red/brown - positive +

Green/Black - OutputOUT

 Yellow / Blue - Negative-

 

.Appearance Size Chart

 

 

 

. Notes

 

1The output line is not directly connected to the high or low level, can drive the load directly, to connect the positive or negative electrode of the power supply after the series load,

2Pay attention to the cleaning of transmitting and receiving port holes, no opaque objects.

 

Online Communication
Mr Yu:15358803325

WeChat Scan
Mr Hao:13915573467