Product Show

Intelligent elevator control equipment

ZK-FC066 face recognition and card swiping system


ZK-FC066 Description of Face Recognition

 

一、Performance parameters

 

Standard voltage

 

DC5V-45V

Working current

<1000ma< span="">

Working temperature

-35℃~70℃

Type of use

IC card, face recognition, mobile phone APP remote door, WeChat temporary access door

User capacity

Unlimited

Face capacity

200,000

Blacklisted capacity

1056 sheets

Recording capacity

 

65,000 articles

Reaction time

<0.5 seconds

Output load

2A 2 4 VDC( Dry node signal)

 

 

Sensing distance

 

Swipe 3-5 cm

 

Mainframe dimensions

 

 

L328×W228×H43mm

 

二、Lead Description

 

 4P port for multi-purpose port: setup download socket, ladder control 4 85 communication port.

 

 9P wiring is marked as follows:

Serial number

Signal

Line colour

 Function Description

 

1

VIN

Red

Power Positive Input

2

GND

Black

Power negative input

3

EN

Yellow

Open button input point

4

NO1

White

Relay output open point

5

COM1

Green

 

Common end

6

NC1

Blue

Relay output normally closed

 

7

Purple

8

DATA1

Brown

W26 output

9

DATA0

Orange

W26 output

 

三、 Controller setup

 

 1. first set up the face recognition host with the card issuer, and restart the system automatically after setting up successfully.

 

 2. external mouse to set device number and related parameters.

 

 Description: The 4-bit dial switch on the main board is used to set the controller function:

 

 1-The output time is fixed to 1 second, and the opening time of the card is not pushed (only for credit card, mobile phone and face door, the opening time is set by the controller). Function card enable. 3- Enable 7.0(latest version 8.0). Turn off roll code anti-replication function.

 

 IV. Wiring schematics

                      

 

                        

 

 

  六、Factory Accessories

 Face recognition host 1;9 P and 4 P insert 1 each; anti-theft

screw 1 set, manual 1.

7. troubleshooting methods

Brush user card controller no response :

 

1、 confirm whether the machine has been set with the cell setup.

2、 card is copied or copied Sound cues:The door rang successfully

3、 The number of card to or write back times failed to ring three times

4、 Permission device address does not match four rings

5、 The card or mobile phone authority does not ring five times within the validity period. It may be that the controller clock is not allowed or the permission has expired

6、 6 sounds during controller disable

7、 Initialization method: push up the 6-bit function switch 1.2.3.4, and do not push the 8-bit address switch. After power on, it will flash all the time. After initialization, the buzzer will sound, which means that the initialization is completed. When the power is off, switch back to the original state and swipe the management card

 

八、Notes

 

This equipment does not do waterproof treatment, avoid installation in wet or Rain Water wet environment. After installation,

 

Online Communication
Mr Yu:15358803325

WeChat Scan
Mr Hao:13915573467